To enable trunking to a device that does not support DTP, use the switchport mode trunk and switchport
nonegotiate interface configuration commands to cause the interface to become a trunk but to not
generate DTP frames.
Configuring an Ethernet Interface as a Trunk Port
Configuring a Trunk Port
Because trunk ports send and receive VTP advertisements, to use VTP you must ensure that at least one trunk
port is configured on the switch and that this trunk port is connected to the trunk port of a second switch.
Otherwise, the switch cannot receive any VTP advertisements.
Before You Begin
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
interface interface-id
4.
switchport mode {dynamic {auto | desirable} | trunk}
5.
switchport access vlan vlan-id
6.
switchport trunk native vlan vlan-id
7.
end
8.
show interfaces interface-id switchport
9.
show interfaces interface-id trunk
10.
copy running-config startup-config
DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode. Enter your password if prompted.enable
Step 1
Example:
Switch> enable
Enters the global configuration mode.configure terminal
Example:
Switch# configure terminal
Step 2
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
2134
How to Configure VLAN Trunks

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals