Related Topics
SNMP Configuration Guidelines, on page 451
Monitoring SNMP Status, on page 467
Configuring SNMP Notifications
A trap manager is a management station that receives and processes traps. Traps are system alerts that the
switch generates when certain events occur. By default, no trap manager is defined, and no traps are sent.
Switches running this Cisco IOS release can have an unlimited number of trap managers.
Many commands use the word traps in the command syntax. Unless there is an option in the command
to select either traps or informs, the keyword traps refers to traps, informs, or both. Use the snmp-server
host global configuration command to specify whether to send SNMP notifications as traps or informs.
Note
You can use the snmp-server host global configuration command for a specific host to receive the notification
types listed in the following table. You can enable any or all of these traps and configure a trap manager to
receive them.
Table 49: Device Notification Types
DescriptionNotification Type Keyword
Generates Border Gateway Protocol (BGP) state change traps. This
option is only available when the IP services feature set is enabled.
bgp
Generates STP bridge MIB traps.bridge
Generates a trap when the cluster configuration changes.cluster
Generates a trap for SNMP configuration changes.config
Generates a trap for SNMP copy configuration changes.copy-config
Allow CPU-related traps.cpu threshold
Generates a trap for SNMP entity changes.entity
Generates environmental monitor traps. You can enable any or all
of these environmental traps: fan, shutdown, status, supply,
temperature.
envmon
Generates SNMP FLASH notifications. In a switch stack, you can
optionally enable notification for flash insertion or removal, which
would cause a trap to be issued whenever a switch in the stack is
removed or inserted (physical removal, power cycle, or reload).
flash
Generates entity field-replaceable unit (FRU) control traps. In the
switch stack, this trap refers to the insertion or removal of a switch
in the stack.
fru-ctrl
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
459
How to Configure SNMP

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals