EasyManuals Logo

Cisco Catalyst 2960 Series User Manual

Cisco Catalyst 2960 Series
2288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1438 background imageLoading...
Page #1438 background image
Configuring 802.1x Readiness Check
The 802.1x readiness check monitors 802.1x activity on all the switch ports and displays information about
the devices connected to the ports that support 802.1x. You can use this feature to determine if the devices
connected to the switch ports are 802.1x-capable.
The 802.1x readiness check is allowed on all ports that can be configured for 802.1x. The readiness check is
not available on a port that is configured as dot1x force-unauthorized.
Follow these steps to enable the 802.1x readiness check on the switch:
Before You Begin
Follow these guidelines to enable the readiness check on the switch:
The readiness check is typically used before 802.1x is enabled on the switch.
If you use the dot1x test eapol-capable privileged EXEC command without specifying an interface,
all the ports on the switch stack are tested.
When you configure the dot1x test eapol-capable command on an 802.1x-enabled port, and the link
comes up, the port queries the connected client about its 802.1x capability. When the client responds
with a notification packet, it is 802.1x-capable. A syslog message is generated if the client responds
within the timeout period. If the client does not respond to the query, the client is not 802.1x-capable.
No syslog message is generated
When you configure the dot1x test eapol-capable command on an 802.1x-enabled port, and the link
comes up, the port queries the connected client about its 802.1x capability. When the client responds
with a notification packet, it is 802.1x-capable. A syslog message is generated if the client responds
within the timeout period. If the client does not respond to the query, the client is not 802.1x-capable.
No syslog message is generated
The readiness check can be sent on a port that handles multiple hosts (for example, a PC that is connected
to an IP phone). A syslog message is generated for each of the clients that respond to the readiness check
within the timer period.
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
dot1x test eapol-capable [interface interface-id]
4.
dot1x test timeout timeout
5.
end
6.
show running-config
7.
copy running-config startup-config
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1356
How to Configure 802.1x Port-Based Authentication

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000