PurposeCommand or Action
Example:
Switch> enable
Configures the hello time of a VLAN. The hello time is the time interval
between configuration messages generated and sent by the root switch.
These messages mean that the switch is alive.
spanning-tree vlan vlan-id hello-time
seconds
Example:
Switch(config)# spanning-tree vlan
20-24 hello-time 3
Step 2
For vlan-id, you can specify a single VLAN identified by VLAN ID
number, a range of VLANs separated by a hyphen, or a series of
VLANs separated by a comma. The range is 1 to 4094.
For seconds, the range is 1 to 10; the default is 2.
Returns to privileged EXEC mode.end
Example:
Switch(config-if)# end
Step 3
Configuring the Forwarding-Delay Time for a VLAN
This procedure is optional.
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
spanning-tree vlan vlan-id forward-time seconds
4.
end
DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode. Enter your password if prompted.enable
Step 1
Example:
Switch> enable
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
235
How to Configure Spanning-Tree Features

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000