DescriptionEnvironment Variable
Consecutive failure, where testnum is the test number.
For example, _gold_cf3 is the EEM built-in
environment variable for consecutive failure of test
3.
_gold_cf testnum
Card index._gold_ci
Card name._gold_cn
Test error code, where testnum is the test number. For
example, _gold_ec3 is the EEM built-in environment
variable for the error code of test 3.
_gold_ec testnum
Last fail time, where testnum is the test number. For
example, _gold_lf3 is the EEM built-in variable for
the last fail time of test 3.
The time-stamp format is mmm dd yyyy hh:mm:ss.
For example, Mar 11 2005 08:47:00.
_gold_lf testnum
The new test failure information in a GOLD event
flag; either true or false.
_gold_new_failure
The overall diagnostic result, which can be one of the
following values:
•
0: OK
•
3: minor error
•
4: major error
•
14: unknown result
_gold_overall_result
Port counts._gold_pc
Test total run count, where testnum is the test number.
For example, _gold_rc3 is the EEM built-in variable
for the total run count of test 3.
_gold_rc testnum
Card serial number._gold_sn
The subcard on which a GOLD failure event was
detected.
_gold_sub_card
Test attribute, where testnum is the test number. For
example, _gold_ta3 is the EEM built-in variable for
the test attribute of test 3.
_gold_ta testnum
Test counts._gold_tc
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1687
Information About Writing EEM Policies Using the Cisco IOS CLI