PurposeCommand or Action
Enters the original domain name on the switch
vtp domain domain-name
Example:
Switch(config)# vtp domain domain012
Step 8
Returns to privileged EXEC mode. The VLAN information on the
switch is updated.
end
Example:
Switch(config)# end
Step 9
(Optional) Verifies that the domain name is the same as in Step 1
and that the configuration revision number is 0.
show vtp status
Example:
Switch# show vtp status
Step 10
Related Topics
VTP Domain, on page 2085
Prerequisites for VTP
Domain Names for Configuring VTP, on page 2090
Monitoring VTP
This section describes commands used to display and monitor the VTP configuration.
You monitor VTP by displaying VTP configuration information: the domain name, the current VTP revision,
and the number of VLANs. You can also display statistics about the advertisements sent and received by the
switch.
Table 191: VTP Monitoring Commands
PurposeCommand
Displays counters about VTP messages that have been
sent and received.
show vtp counters
Displays information about all VTP version 3 devices in
the domain. Conflicts are VTP version 3 devices with
conflicting primary servers. The show vtp devices
command does not display information when the switch
is in transparent or off mode.
show vtp devices [conflict]
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
2104
Monitoring VTP

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000