C613-50100-01 REV C Command Reference for x930 Series 3012
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
TRIGGER COMMANDS
SHOW
TRIGGER
To display detailed information about trigger 3, use the command:
awplus# show trigger 3
Figure 63-3: Example output from the show trigger command for a specific
trigger
To display detailed information about all triggers, use the command:
awplus# show trigger full
Ac Whether the trigger is active (Y), or inactive (N).
Te Whether the trigger is in test mode (Y) or not (N).
Tr Whether or not the trigger is enabled to send SNMP traps. See the trap
command.
Repeat Whether the trigger repeats continuously, and if not, the configured
repeat count for the trigger. To see the number of times a trigger has
activated, use the show trigger <1-250> command.
#Scr Number of scripts associated with the trigger.
Days/Date Days or date when the trigger may be activated. For the days options,
the days are shown as a seven character string representing Sunday to
Saturday. A hyphen indicates days when the trigger cannot be
activated.
awplus#show trigger 3
Trigger Configuration Details
------------------------------------------------------------
Trigger ..................... 1
Description ................. display cpu usage when pass 80%
Type and details ............ CPU (80% up)
Days ........................ 26-oct-2016
After ....................... 00:00:00
Before ...................... 23:59:59
Active ...................... Yes
Test ........................ No
Trap ........................ Yes
Repeat ...................... 123 (0)
Modified .................... Tue Oct 25 02:26:03 2016
Number of activations ....... 0
Last activation ............. not activated
Number of scripts ........... 1
1. shocpu.scp
2. <not configured>
3. <not configured>
4. <not configured>
5. <not configured>
------------------------------------------------------------
Table 2: Parameters in the output of the show trigger command (cont.)