C613-50100-01 REV C Command Reference for x930 Series 321
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PLUGGABLES AND CABLING COMMANDS
SHOW
SYSTEM PLUGGABLE DETAIL
Device Revision Specifies the hardware revision code for the pluggable
transceiver. This may be useful for troubleshooting because
different devices may support different pluggable
transceiver revisions.
Device Type Specifies the device type for the installed pluggable
transceiver..
Serial Number Specifies the serial number for the installed pluggable
transceiver.
Manufacturing
Datecode
Specifies the manufacturing datecode for the installed
pluggable transceiver. Checking the manufacturing
datecode with the vendor may be useful when
determining Laser Diode aging issues. For more
information, see ”How To Troubleshoot Fiber and
Pluggable Issues” in the “Getting Started with AlliedWare
Plus” Feature Overview and Configuration Guide.
SFP Laser Wavelength Specifies the laser wavelength of the installed pluggable
transceiver.
Single Mode Fiber Specifies the link length supported by the pluggable
transceiver using single mode fiber.
OM1 (62.5um) Fiber Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 62.5 micron multi-mode fiber.
OM2 (50um) Fiber Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 50 micron multi-mode fiber.
Diagnostic Calibration Specifies whether the pluggable transceiver supports DDM
or DOM Internal or External Calibration:
Internal is displayed if the pluggable transceiver supports
DDM or DOM Internal Calibration.
External is displayed if the pluggable transceiver supports
DDM or DOM External Calibration.
- is displayed if neither Internal Calibration or External
Calibration is supported.
Power Monitoring Displays the received power measurement type, which can
be either OMA (Optical Module Amplitude) or Avg
(Average Power) measured in μW.
TX power monitor
support
For QSFP+ modules, indicates whether the module
supports monitoring of the transmitted optical power level
(Yes or No). If yes, you can view the average output optical
power in the output of the command show system
pluggable diagnostics.
Table 10: Parameters in the output from the show system pluggable detail
command: (cont.)
Parameter Description