C613-50100-01 REV C Command Reference for x930 Series 325
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PLUGGABLES AND CABLING COMMANDS
SHOW
SYSTEM PLUGGABLE DIAGNOSTICS
module in port 1.1.2. Note that the output displays each internal
channel separately.
awplus#show sys pluggable diagnostics
System Pluggable Information Diagnostics
Port1.1.1
Diagnostics information is not supported by device DM-317-100
Port1.1.2 Status Alarms Warnings
Reading Alarm Max Min Warning Max Min
Temp: (Degrees C) 23.211 - 75.000 -5.000 - 70.000 -
Vcc: (Volts) 3.301 - 3.630 2.970 - 3.465 3.135
Channel 1:
Tx Bias: (mA) 6.696 - 10.000 0.500 - 9.500 1.000
Tx Power: (mW) 0.682 - - - - - -
Rx Power: (mW) - Low 2.188 0.045 Low 1.738 0.112
Rx LOS: Rx Down
Channel 2:
Tx Bias: (mA) 6.416 - 10.000 0.500 - 9.500 1.000
Tx Power: (mW) 0.684 - - - - - -
Rx Power: (mW) - Low 2.188 0.045 Low 1.738 0.112
Rx LOS: Rx Down
Channel 3:
Tx Bias: (mA) 6.428 - 10.000 0.500 - 9.500 1.000
Tx Power: (mW) 0.685 - - - - - -
Rx Power: (mW) - Low 2.188 0.045 Low 1.738 0.112
Rx LOS: Rx Down
Channel 4:
Tx Bias: (mA) 6.748 - 10.000 0.500 - 9.500 1.000
Tx Power: (mW) 0.670 - - - - - -
Rx Power: (mW) - Low 2.188 0.045 Low 1.738 0.112
Rx LOS: Rx Down
Table 11: Parameters in the output from the show system pluggables
diagnostics command
Parameter Description
Temp (Degrees C) Shows the temperature inside the transceiver.
Vcc (Volts) Shows voltage supplied to the transceiver.
Tx Bias (mA) Shows current to the Laser Diode in the transceiver.
Tx Power (mW) Shows the amount of light transmitted from the transceiver.
Rx Power (mW) Shows the amount of light received in the transceiver.
Rx LOS Rx Loss of Signal. This indicates whether:
light is being received (Rx Up) and therefore the link is up, or
light is not being received (Rx Down) and therefore the link is
down