Chapter 41: Logging
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1052
Note: Reduce the local log size from the default of 10 only if you want the
C4/c CMTS to reduce the number of events logged.
Use the [no] option to disable volatile local logging for all logging levels.
See also see "Configure Local Logging Level (page
1052), see "Disable Specific Local Logging Level (page
1052), and see "Configure Local Log Size (page 1052).
Used to display the current logging configuration and utilization statistics
for the local volatile log.
show logging local
See also see "Disable Specific Local Logging Level
(page 1052).
Configure Local Logging Level
The following command sets events to report for priority level 7:
configure logging local-volatile 7
Disable Specific Local Logging Level
The following command inhibits priority level 6 event messages for the local volatile log:
configure logging local-volatile 6 no
Note: This command will fail if the specified priority is not first disabled for Syslog and SNMP. See the sample error
message that follows:
Priority 6 must be disabled for Syslog and SNMP before it can be disabled for local-volatile
Error: Bad command
Configure Local Log Size
The following command example changes the number of events maintained in the local logs to 100:
configure logging local-volatile size 100
By default, the C4/c CMTS maintains the 10 most recent event types in the local volatile log.