Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1952
configure interface loopback * isis metric
Purpose
Configures the default metric for the specified interface.
Default Access Level
15
Command Syntax
configure interface loopback <0-15> isis metric <default-metric> [<level1 | level2>]
configure interface loopback <0-15> isis metric [<level1 | level2>] no
Supplemental
Information
This command only applies when IPv6 is not used in the system.
To restore the default value, use the no option.
Parameters
<0-15>
The Loopback interface number. Valid range is 0 to 15.
<default-metric>
Integer. Valid range is 1-63.
[<level1 | level2>]
Specifies the type of adjacencies to be formed on this interface. If no value is specified, then modify value for both level-1 and level-
2.