configure interface cable-upstream * cable connector
Purpose
.Configures the upstream connector on the PIC of the specified UCAM.
Default Access Level
15
Command Syntax
configure interface cable-upstream <s/ch> cable connector <number>
configure interface cable-upstream <s/ch> cable connector <number> no
Supplemental
Information
To remove an upstream connector, use the no option
Parameters
<s/ch>
The upstream slot/channel.
<number>
Connector range is 0-23 and is dependent on the cable-upstream specified.