configure fan monitor * shutdown
Purpose
Disables the specified fan monitor.
Default Access Level
15
Command Syntax
configure fan monitor <0-2> shutdown
configure fan monitor <0-2> shutdown no
Supplemental
Information
Fan monitoring is on by default.
Use the no option of the command to restore the fan monitor.
Parameters
<0-2>
Fan unit number. Fan units are number 0, 1 or 2.