Chapter 41: Logging
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1059
Description
Command
Used to specify the recipient (SNMP manager) of an SNMP trap
or informs notification.
Use the [no] option to remove the recipient (SNMP manager) of
an SNMP trap or notification information.
configure snmp-server host <ip address> [udp-port
<port> [notification type <traps | informs>]
[version <v1 | v2c | v3>] [rowstatus <rowstatus>]
[timeout <timeout>] [retry <number>] [notify-
filter <std-filter-profile|userdefined-filter-
profile>] [taglist <value>] [tparam <value>]
[mask <targetaddr mask>] [mms <max-message-size>]
[no]
See also see "Configure SNMP Server to Existing Network
(page 1059).
Used to display the current SNMP logging related information.
show logging snmp
See also see "Display SNMP Utilization Statistics (page 1060).
Generate Trap for Priority 7
This command example generates SNMP traps for informational messages (event priority 7):
configure logging snmp 7
Note: This command will fail if the priorities are not first enabled for the local volatile log.
Disable Trap for Priority 7
This command example turns off SNMP traps for informational messages (event priority 7):
configure logging snmp 7 no
Configure SNMP Server to Existing Network
This command example configures the SNMP server to IP address 10.16.1.1:
configure snmp-server host 10.16.1.1