Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1708
configure interface cable-upstream * cable max-power-adj
Purpose
Sets the maximum cable modem power adjustment per range response message.
Default Access Level
15
Command Syntax
configure interface cable-upstream <slot/ch> cable max-power-adj <power adjustment>
Supplemental
Information
The Rx power can be adjusted to any level from -16 to 26 dBmV.
Parameters
<slot/ch>
The upstream slot/channel. It will assume lc=0 if needed and not supplied.
<power
adjustment>
Maximum size of the C4 CMTS range response power adjustments in 1/4 dBmV units. Valid range is 1-48. Default is set at 24 units