Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1960
configure interface tengigabitethernet * description
Purpose
Allows you to add a comment or a description to help you remember what is attached to this interface.
Default Access Level
15
Command Syntax
configure interface tengigabitethernet <slot>/<port>[.0-254] description <text>
configure interface tengigabitethernet <slot>/<port>[.0-254] description no
Supplemental
Information
To remove the description, use the no option.
Parameters
<slot>/<port>[.0-
254]
RCM slot number/tengigabitEthernet port number[.subinterface number].
Valid range for the C4 CMTS is <17-18>/<10>
Valid range for the C4c CMTS is <17>/<10>
<text>
Descriptive information, e.g., identifies area served. Text is limited to 32 characters.