Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1433
configure cable spectrum-group * state * trigger
Defines the trigger conditions of the Frequency Agility State Machine.
configure cable spectrum-group <sm_ID> state <1-16> trigger <1-64> next-state <1-16>
configure cable spectrum-group <sm_ID> state <1-16> trigger <1-64> no
To reset to the default state, use the no option.
Parameters
The number of the spectral group and has a value from 1-40.
Pointer to the unique state within state machine.
Trigger ID (can be used by all state machines).