Chapter 9: Upstream Cable Access Modules (UCAMs)
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 321
SCDMA Spreader Enable
According to the DOCSIS RFI specification, if SCDMA is enabled, IUC 3 must have the spreader off and the IUCs 1, 9, 10 and
11 must have the spreader on. This only leaves IUC 4. The specification states that it can have the spreader on or off.
However, the current version of the software only supports spreader off for IUC 4. Therefore, all of the values for the
spreader must remain the same as what is currently in the default modulation profiles. This is shown in the show cable
modulation-profile command in the Scdma Sp En column.
SCDMA Codes Per Subframe
This parameter is used in with the SCDMA interleaver step size to determine how data is interleaved with SCDMA. This
parameter is shown in the show cable modulation-profile command in the Scdma Sub Code column.
When interleaving with SCDMA, preamble and TCM-encoded symbols are interleaved in one way and non-TCM-encoded
symbols are interleaved in another. This parameter has the greatest effect on the preamble and TCM-encoded symbols.
Since in general TCM is not recommended, this simply leaves the preamble symbols. As such this parameter does not tend
to have much effect on the overall performance of the system.