EasyManua.ls Logo

Arris C4C - Сonfigure Cable Unicast-Polling Pri

Arris C4C
3180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1446
configure cable unicast-polling pri
Purpose
Configures the settings for unicast polling priorities.
Default Access Level
15
Command Syntax
configure cable unicast-possing pri <0-7> [slow-intvl <20-1000>] [fast-intvl <20-10000>] [fast-period
<20-50000>]
configure cable unicast-possing pri <0-7> [slow-intvl <20-1000>] [fast-intvl <20-10000>] [fast-period
<20-50000>] no
Supplemental
Information
To reset the unicast polling priorities, use the no option.
Parameters
<0-7>
DOCSIS service flow priority
[slow-intvl <20-
1000>]
Slow poll interval, units in tens of milliseconds
[fast-intvl <20-
10000>]
Fast poll interval, units in tens of milliseconds
[fast-period <20-
50000>]
Fast poll timeout period, units in tens of milliseconds

Table of Contents

Related product manuals