Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1446
configure cable unicast-polling pri
Purpose
Configures the settings for unicast polling priorities.
Default Access Level
15
Command Syntax
configure cable unicast-possing pri <0-7> [slow-intvl <20-1000>] [fast-intvl <20-10000>] [fast-period
<20-50000>]
configure cable unicast-possing pri <0-7> [slow-intvl <20-1000>] [fast-intvl <20-10000>] [fast-period
<20-50000>] no
Supplemental
Information
To reset the unicast polling priorities, use the no option.
Parameters
<0-7>
DOCSIS service flow priority
[slow-intvl <20-
1000>]
Slow poll interval, units in tens of milliseconds
[fast-intvl <20-
10000>]
Fast poll interval, units in tens of milliseconds
[fast-period <20-
50000>]
Fast poll timeout period, units in tens of milliseconds