configure interface tengigabitethernet * isis metric
Purpose
Configures the default metric for the specified interface.
Default Access Level
15
Command Syntax
configure interface tengigabitethernet <slot>/<port>[.<0-254>] isis metric <default-metric> [<level1 |
level2>]
configure interface tengigabitethernet <slot>/<port>[.<0-254>] isis metric [<level1 | level2>] no
Supplemental
Information
This command only applies when IPv6 is not used in the system.
To restore the default value, use the no option.
Parameters
<slot>/<port>[.<0-
254>]
RCM slot number/tengigabitEthernet port number[.subinterface number].
Valid range for the C4 CMTS is <17-18>/<10>[.<0-254>]
Valid range for the C4c CMTS is <17>/<10>[.<0-254>]
<default-metric>
Integer. Valid range is 1-63.
[<level1 | level2>]
Specifies the type of adjacencies to be formed on this interface. If no value is specified, then modify value for both level-1 and level-
2.