configure interface cable-upstream * cable supervision
Purpose
Configures the supervisory downstream for the specified upstream.
Default Access Level
15
Command Syntax
configure interface cable-upstream <slot/ch> cable supervision <s/c/rng>
configure interface cable-upstream <slot/ch> cable supervision <s/c/rng> no
Supplemental
Information
Note: Both upstream and downstream channels must belong to the same cable-mac before invoking this command.
To disable source verification on the specified slot and downstream port, use the no option.
US Channel Width in kHz Valid Rx Power Range (dBmV)
200 -16 to +14 (-13 to +14 is recommended)
400 -13 to +17
800 -13 to +20 (-13 to +17 is recommended)
1600 -13 to +23 (-13 to +17 is recommended)
3200 -10 to +26 (-10 to +20 is recommended)
6400 -7 to +29 (-7 to +23 is recommended)
Parameters
<slot/ch>
The upstream slot/channel
<s/ch>
The downstream slot/channel.
Related Commands
show interface cable-mac (page 2796)
configure interface cable-upstream * cable cable-mac (page 1698)
configure interface cable-downstream * cable channel-id (page 1470)
show cable supervision (page 2746)