Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1507
configure interface cable-mac * cable cm-status event-type * max-event-holdoff
Purpose
Configures the holdoff timer to be used by the CM when determining when to transmit a CM-STATUS message.
Default Access Level
15
Command Syntax
configure interface cable-mac <mac> cable cm-status event-type <all|type> max-event-holdoff <1-65535>
configure interface cable-mac <mac> cable cm-status event-type <all|type> max-event-holdoff <1-65535> no
Supplemental
Information
To restore the default value, use the no option.
Parameters
<mac>
The MAC identifier. Valid numbers are 0-415.
<all>
Includes all event types
<type>
Select from the following event condition types:
secondaryChlMddTimeout
qamFecLockFailure
seqOutOfRange
mddRecovery
qamFecLockRecovery
t4Timeout
t3RetriesExceeded
t3RangingRecovery
cmOnBatteryBackup
cmAcPowerRestored
all
<1-65535>
Maximum value of holdoff timer in ticks. One tick = 20 milliseconds. Default = 15 ticks (30 seconds).