EasyManua.ls Logo

Arris C4C - Display Event Throttle Settings; Configure Throttling; Change Event Throttle Type

Arris C4C
3180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 41: Logging
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1068
Display Event Throttle Settings
Use the following command to show the configured throttle settings and utilization statistics.
show logging throttle
An output similar to the following example is returned:
Throttle: type=unconstrained, threshold=0, interval=1, notifications=23, throttled=0
Configure Throttling
Use the following command example sequence to throttle logging to 1 event per second:
configure logging throttle threshold 1
configure logging throttle interval 1
configure logging throttle limit
Use the following command to display the logging configuration:
show logging
An output similar to the following example is returned:
Throttle: type=limit, threshold=1, interval=1, notifications=1356, throttled=85
Note: The C4/c CMTS displays the logging settings, including how many event messages have been throttled.
Wait five seconds to allow the C4/c CMTS to refresh and display the logging configuration again:
show logging
An output similar to the following example is returned:
Throttle: type=limit, threshold=1, interval=1, notifications=1405, throttled=113
Note: This second output shows that the number of throttled event messages has risen to 113.
Change Event Throttle Type
Use this command form (with the correct option), if throttling conditions permit, to reset the throttling type to the default,
or permit unconstrained configuration:
configure logging throttle [limit|stop|all|interval|threshold] [no]
Where: limit = to enable message rate limiting at a given threshold

Table of Contents