EasyManua.ls Logo

Arris C4C - Сonfigure Interface Cable-Downstream Cable Power-Level

Arris C4C
3180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1482
configure interface cable-downstream * cable power-level
Purpose
Sets operational transmit power in tenths of a dBmV for the specified downstream port.
Default Access Level
15
Command Syntax
configure interface cable-downstream <slot/port> cable power-level <power level in dBmV>
Supplemental
Information
Use any multiple of 10 in the range of 410-600 for the power-level value. This is in compliance with the DOCSIS MIB. However, the
CMTS supports power accuracy only to the decibel per millivolt.
Parameters
<slot>
The chassis slot in which the targeted downstream Cable Access Module resides. Valid range for the C4 CMTS is 0-15; valid range for
the C4c CMTS is 10-15.
<port>
The downstream port.
<power level in
dBmV>
The power level indicated in tenths of a dBmV for the specified downstream port. Valid range is from 410-600 tenths of a dBmV (41-
60 dBmV). The default is 490.

Table of Contents