configure interface cable-downstream * cable power-level
Sets operational transmit power in tenths of a dBmV for the specified downstream port.
configure interface cable-downstream <slot/port> cable power-level <power level in dBmV>
Use any multiple of 10 in the range of 410-600 for the power-level value. This is in compliance with the DOCSIS MIB. However, the
CMTS supports power accuracy only to the decibel per millivolt.
Parameters
The chassis slot in which the targeted downstream Cable Access Module resides. Valid range for the C4 CMTS is 0-15; valid range for
the C4c CMTS is 10-15.
The power level indicated in tenths of a dBmV for the specified downstream port. Valid range is from 410-600 tenths of a dBmV (41-
60 dBmV). The default is 490.