Loading...
LIN Controller (LINFlex) RM0046
496/936 Doc ID 16912 Rev 5
Table 238. LINIER field descriptions
Field Description
SZIE
Stuck at Zero Interrupt Enable
0 No interrupt when SZF bit in LINESR or UARTSR is set.
1 Interrupt generated when SZF bit in LINESR or UARTSR is set.
OCIE
Output Compare Interrupt Enable
0 No interrupt when OCF bit in LINESR or UARTSR is set.
1 Interrupt generated when OCF bit in LINESR or UARTSR is set.
BEIE
Bit Error Interrupt Enable
0 No interrupt when BEF bit in LINESR is set.
1 Interrupt generated when BEF bit in LINESR is set.
CEIE
Checksum Error Interrupt Enable
0 No interrupt on Checksum error.
1 Interrupt generated when checksum error flag (CEF) in LINESR is set.
HEIE
Header Error Interrupt Enable
0 No interrupt on Break Delimiter error, Synch Field error, Identifier field error.
1 Interrupt generated on Break Delimiter error, Synch Field error, Identifier field error.
FEIE
Framing Error Interrupt Enable
0 No interrupt on Framing error.
1 Interrupt generated on Framing error.
BOIE
Buffer Overrun Interrupt Enable
0 No interrupt on Buffer overrun.
1 Interrupt generated on Buffer overrun.
LSIE
LIN State Interrupt Enable
0 No interrupt on LIN state change.
1 Interrupt generated on LIN state change.
This interrupt can be used for debugging purposes. It has no status flag but is reset when writing
‘1111’ into LINS[0:3] in the LINSR.
WUIE
Wake-up Interrupt Enable
0 No interrupt when WUF bit in LINSR or UARTSR is set.
1 Interrupt generated when WUF bit in LINSR or UARTSR is set.
DBFIE
Data Buffer Full Interrupt Enable
0 No interrupt when buffer data register is full.
1 Interrupt generated when data buffer register is full.
DBEIE
Data Buffer Empty Interrupt Enable
0 No interrupt when buffer data register is empty.
1 Interrupt generated when data buffer register is empty.
DRIE
Data Reception Complete Interrupt Enable
0 No interrupt when data reception is completed.
1 Interrupt generated when data received flag (DRF) in LINSR or UARTSR is set.
DTIE
Data Transmitted Interrupt Enable
0 No interrupt when data transmission is completed.
1 Interrupt generated when data transmitted flag (DTF) is set in LINSR or UARTSR.