General Configuration Command Set
Setting Basic Device Properties
Matrix DFE-Platinum and Diamond Series Configuration Guide 2-83
2.2.3.33 show physical alias
Use this command to display the alias, a text name, for one or more physical objects.
show physical alias [chassis] | [slot slot] | [backplane backplane] | [module
module] | [powersupply powersupply] | [powersupply-slot powersupply-slot] |
[fan] | [fan-slot] | [port-string port-string]
Syntax Description
Command Defaults
If no parameters are specified, all physical alias information will be displayed.
Command Type
Switch command.
Command Mode
Read-Only.
chassis (Optional) Displays the alias set for the chassis.
slot slot (Optional) Displays the alias set for a specified slot in the
chassis.
backplane
backplane
(Optional) Displays the alias set for the backplane. Valid
values are 1 for FTM 1 and 2 for FTM 2.
module module (Optional) Displays the alias set for a specified module. A
maximum of one module alias per slot is allowed.
powersupply
powersupply
(Optional) Displays the alias set for a specified power
supply. Valid values are 1 or 2.
powersupply-slot
powersupply-slot
(Optional) Displays an alias set for a specific power
supply slot.
fan (Optional) Displays the alias set for the fan tray.
fan-slot (Optional) Displays an alias for the fan tray’s slot.
port-string
port-string
(Optional) Displays the alias set for a specified
port-string. For a detailed description of possible
port-string values, refer to Section 4.1.1.