Loading...
VLAN Configuration Command Set
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
Matrix DFE-Platinum and Diamond Series Configuration Guide 7-17
7.3.3.4 show vlan interface
Use this command to display the MIB-II interface entry mapped to a VLAN.
show vlan interface [vlan-list]
Syntax Description
Command Defaults
If vlan-list is not specified, MIB2 interface entries will be displayed for all VLANs.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display the interface entry for VLAN 1:
Table 7-2 provides an explanation of the command output.
vlan-list Displays the MIB2 interface entry for specific VLAN(s).
Matrix(rw)->show vlan interface 1
VLAN Port Storage Type
-------------------------------------
1 vlan.0.1 non-volatile
Table 7-2 show vlan interface Output Details
Output What It Displays...
VLAN VLAN ID.
Port Port-string designation.
Storage Type Whether the entry is stored as a volatile or non-volatile
entry. Volatile entries are lost when a system is reset.
Non-volatile entries are saved in NVRAM and are persistent
until cleared.