Page #328 background image
Port Configuration Command Set
Configuring Link Traps and Link Flap Detection
4-68 Matrix DFE-Platinum and Diamond Series Configuration Guide
4.3.8.1 show port trap
Use this command to display whether the port is enabled for generating an SNMP trap message if
its link state changes.
show port trap [port-string]
Syntax Description
Command Defaults
If port-string is not specified, the trap status for all ports will be displayed.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to display link trap status for fe.3.1 through 4:
port-string (Optional) Displays link trap status for specific port(s). For
a detailed description of possible port-string values, refer to
Section 4.1.1.
Matrix(rw)->show port trap fe.3.1-4
Link traps enabled on port fe.3.1.
Link traps enabled on port fe.3.2.
Link traps enabled on port fe.3.3.
Link traps enabled on port fe.3.4.