EasyManua.ls Logo

Enterasys Matrix 2G4072-52 - Set Spantree Lpwindow

Enterasys Matrix 2G4072-52
1422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spanning Tree Configuration Command Set
Configuring Spanning Tree Loop Protect Features
Matrix DFE-Platinum and Diamond Series Configuration Guide 6-133
6.2.3.12 set spantree lpwindow
Use this command to set the Loop Protect event window value in seconds.
set spantree lpwindow value
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Usage
The Loop Protect Window is a timer value, in seconds, that defines a period during
which Loop Protect events are counted. The default value is 180 seconds. If the
timer is set to 0, the event counter is not reset until the Loop Protect event threshold
is reached. If the threshold is reached, that constitutes a loop protection event.
Example
This example shows how to set the Loop Protect event window to 120 seconds:
value Specifies the number of seconds that comprise the period
during which Loop Protect events are counted. The default
event window is 180 seconds.
Matrix(rw)->set spantree lpwindow 120

Table of Contents

Related product manuals