EasyManua.ls Logo

Enterasys Matrix 2G4072-52 - Set Spantree Txholdcount

Enterasys Matrix 2G4072-52
1422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spanning Tree Configuration Command Set
Configuring Spanning Tree Bridge Parameters
6-62 Matrix DFE-Platinum and Diamond Series Configuration Guide
6.2.1.49 set spantree txholdcount
Use this command to set the maximum BPDU transmission rate. This is the number of BPDUs
which will be transmitted before transmissions are subject to a one-second timer.
set spantree txholdcount txholdcount
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to globally set the transmit hold count to 5:
txholdcount Specifies the maximum number of BPDUs to be
transmitted before transmissions are subject to a
one-second timer. Valid values are 1 - 10. Default value
is 6.
Matrix(rw)->set spantree txholdcount 5

Table of Contents