VLAN Configuration Command Set
Enabling/Disabling GVRP
7-40 Matrix DFE-Platinum and Diamond Series Configuration Guide
7.3.6.1 show gvrp
Use this command to display GVRP configuration information.
show gvrp [port-string]
Syntax Description
Command Defaults
If port-string is not specified, GVRP configuration information will be displayed
for all ports and the device.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display GVRP status for the device and for Fast Ethernet port 1 in
module 2:
Table 7-5 provides an explanation of the command output.
port-string (Optional) Displays GVRP configuration information for
specific port(s). For a detailed description of possible
port-string values, refer to Section 4.1.1.
Matrix(rw)->show gvrp fe.2.1
Global GVRP status is enabled.
Port Number GVRP status Last PDU Origin
----------- ----------- -----------------
fe.2.1 enabled 00-e0-63-97-d4-36
Table 7-5 show gvrp Output Details
Output What It Displays...
Port Number Port designation. For a detailed description of possible
port-string values, refer to Section 4.1.1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix 2G4072-52 and is the answer not in the manual?

Enterasys Matrix 2G4072-52 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix 2G4072-52
CategorySwitch
LanguageEnglish

Related product manuals