Security Configuration Command Set
Configuring Flow Setup Throttling (FST)
14-204 Matrix DFE-Platinum and Diamond Series Configuration Guide
14.3.15.11 set flowlimit notification
Use this command to enable or disable flow limit notification, or to set a notification interval. When
enabled, this allows ports configured with a “trap” action to send an SNMP trap message when a
specified flow limit is reached. For information on using the set flowlimit limit command to
configure a trap action on a port, refer to Section 14.3.15.3.
set flowlimit notification {disable | enable | interval}
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to enable the flow limit notification function:
disable | enable Disables or enables SNMP notification.
interval Specifies a notification interval (in seconds) for SNMP trap
messages. Valid values are 0 - 4294967295.
Matrix(rw)->set flowlimit notification enable