Logging And Network Management Command Set
Configuring RMON
11-62 Matrix DFE-Platinum and Diamond Series Configuration Guide
11.2.4.10 clear rmon alarm
Use this command to delete an RMON alarm entry.
clear rmon alarm index
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to clear RMON alarm entry 1:
index Specifies the index number of entry to be cleared.
Matrix(rw)->clear rmon alarm 1