General Configuration Command Set
Configuring Power over Ethernet (PoE)
2-110 Matrix DFE-Platinum and Diamond Series Configuration Guide
2.2.5.13 clear inlinepower management
Use this command to reset the PoE management mode on a specified module back to the default
setting of “realtime”.
clear inlinepower management module-number
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to reset the PoE management mode to “realtime” on module 1:
module-number Specifies the module on which to reset the PoE
management mode.
Matrix(rw)->clear inlinepower management 1