EasyManua.ls Logo

Enterasys Matrix 2G4072-52 - Clear Inlinepower Management

Enterasys Matrix 2G4072-52
1422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Configuration Command Set
Configuring Power over Ethernet (PoE)
2-110 Matrix DFE-Platinum and Diamond Series Configuration Guide
2.2.5.13 clear inlinepower management
Use this command to reset the PoE management mode on a specified module back to the default
setting of “realtime”.
clear inlinepower management module-number
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to reset the PoE management mode to “realtime” on module 1:
module-number Specifies the module on which to reset the PoE
management mode.
Matrix(rw)->clear inlinepower management 1

Table of Contents