Page #857 background image
Logging And Network Management Command Set
Configuring RMON
Matrix DFE-Platinum and Diamond Series Configuration Guide 11-67
11.2.4.13 set rmon event status
Use this command to enable an RMON event entry. An event entry describes the parameters of an
RMON event that can be triggered. Events can be fired by RMON alarms and can be configured to
create a log entry, generate a trap, or both.
set rmon event status index enable
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to enable RMON event entry 1:
NOTE: An RMON event entry can be created using this command, configured using
the
set rmon event properties command (Section 11.2.4.12), then enabled using
this command. An RMON event entry can be created and configured at the same time
by specifying an unused index with the set properties command.
index Specifies an index number for this entry. Maximum
number of entries is 100. Maximum value is 65535.
enable Enables this event entry.
Matrix(rw)->set rmon event status 1 enable

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix 2G4072-52 and is the answer not in the manual?

Enterasys Matrix 2G4072-52 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix 2G4072-52
CategorySwitch
LanguageEnglish

Related product manuals