Logging And Network Management Command Set
Configuring RMON
Matrix DFE-Platinum and Diamond Series Configuration Guide 11-61
11.2.4.9 set rmon alarm status
Use this command to enable an RMON alarm entry. An alarm is a notification that a statistical
sample of a monitored variable has crossed a configured threshold.
set rmon alarm status index enable
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to enable RMON alarm entry 3:
NOTE: An RMON alarm entry can be created using this command, configured using
the
set rmon alarm properties command (Section 11.2.4.8), then enabled using this
command. An RMON alarm entry can be created and configured at the same time by
specifying an unused index with the set properties command.
index Specifies an index number for this entry. Maximum
number or entries is 50. Maximum value is 65535.
enable Enables this alarm entry.
Matrix(rw)->set rmon alarm status 3 enable