Discovery Protocols Command Set
Enterasys Discovery Protocol
Matrix DFE-Platinum and Diamond Series Configuration Guide 3-9
3.2.2.4 set cdp interval
Use this command to set the message interval frequency (in seconds) of the CDP discovery
protocol.
set cdp interval frequency
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the CDP interval frequency to 15 seconds:
frequency Specifies the transmit frequency of CDP messages in
seconds.Valid values are from 5 to 900 seconds.
Matrix(rw)->set cdp interval 15