Discovery Protocols Command Set
Link Layer Discovery Protocol and LLDP-MED
3-42 Matrix DFE-Platinum and Diamond Series Configuration Guide
3.2.4.9 set lldp tx-interval
Use this command to set the time, in seconds, between successive LLDP frame transmissions
initiated by changes in the LLDP local system information.
set lldp tx-interval frequency
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example sets the transmit interval to 20 seconds.
frequency Specifies the number of seconds between transmissions of
LLDP frames. Value can range from 5 to 32,768 seconds.
The default is 30 seconds.
Matrix(rw)->set lldp tx-interval 20