SNMP Configuration Command Set
Configuring SNMP Notification Parameters
5-58 Matrix DFE-Platinum and Diamond Series Configuration Guide
5.3.7.4 show snmp notifyfilter
Use this command to display SNMP notify filter information, identifying which profiles will not
receive SNMP notifications.
show snmp notifyfilter [profile] [subtree oid-or-mibobject] [volatile |
nonvolatile | read-only]
Syntax Description
Command Defaults
If no parameters are specified, all notify filter information will be displayed.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display SNMP notify filter information. In this case, the notify profile
“pilot1” in subtree 1.3.6 will not receive SNMP notification messages:
profile (Optional) Displays a specific notify filter.
subtree
oid-or-mibobject
(Optional) Displays a notify filter within a specific
subtree.
volatile |
nonvolatile |
read-only
(Optional) Displays notify filter entries of a specific
storage type.
Matrix(rw)->show snmp notifyfilter
--- SNMP notifyFilter information ---
Profile = pilot1
Subtree = 1.3.6
Filter type = included
Storage type = nonVolatile
Row status = active

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix 2G4072-52 and is the answer not in the manual?

Enterasys Matrix 2G4072-52 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix 2G4072-52
CategorySwitch
LanguageEnglish

Related product manuals