Port Configuration Command Set
Setting Console Port Properties
4-10 Matrix DFE-Platinum and Diamond Series Configuration Guide
4.3.1.4 set console baud
Use this command to set the baud rate for one or more console ports.
set console baud rate [port-string]
Syntax Description
Command Defaults
If port-string is not specified, baud rate will be set for all console ports.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the baud rate to 19200 on console port com.1.1:
rate Sets the console baud rate. Valid values are: 300, 600, 1200,
2400, 4800, 5760, 9600, 14400, 19200, 38400, and 115200.
port-string (Optional) Sets baud rate for specific port(s).
Matrix(rw)->set console baud 19200 com.1.1