EasyManuals Logo

Enterasys Matrix 2G4072-52 User Manual

Enterasys Matrix 2G4072-52
1422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #949 background imageLoading...
Page #949 background image
Logging And Network Management Command Set
Configuring NetFlow
Matrix DFE-Platinum and Diamond Series Configuration Guide 11-159
11.2.8.4 set netflow export-destination
Use this command to configure the NetFlow collector destination. By default, no collector address
is configured. Only one collector destination per Matrix system can be configured.
set netflow export-destination ip-address [udp-port]
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write
Example
This example shows how to set the IP address of the NetFlow collector
:
ip-address Specifies the IP address of the NetFlow collector.
udp-port (Optional) Specifies the UDP port number used by the
NetFlow collector. Default is 2055.
Matrix(rw)->set netflow export-destination 10.10.1.1