Security Configuration Command Set
Configuring Flow Setup Throttling (FST)
Matrix DFE-Platinum and Diamond Series Configuration Guide 14-203
14.3.15.10set flowlimit shutdown
Use this command to enable or disable the flow limit shut down function. When enabled, this allows
ports configured with a “disable” action to shut down. For information on using the set flowlimit
limit command to configure set a disable action on a port, refer to Section 14.3.15.3.
set flowlimit shutdown {enable | disable}
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to enable the flow limit shut down function:
enable | disable Enables or disables the flow limit shut down function.
Matrix(rw)->set flowlimit shutdown enable