EasyManua.ls Logo

Enterasys Matrix 2G4072-52 - Page 1112

Enterasys Matrix 2G4072-52
1422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Routing Protocol Configuration Command Set
Configuring RIP
13-10 Matrix DFE-Platinum and Diamond Series Configuration Guide
13.2.2.6 timers
Use this command to adjust RIP routing timers determining the frequency of routing updates, the
length of time before a route becomes invalid, and the interval during which routing information
regarding better paths is suppressed.
timers basic update-seconds invalid-seconds holdown-seconds flush-seconds
Syntax Description
Command Syntax of the “no” Form
The “no” form of this command clears RIP timer parameters:
no timers basic
Command Type
Router command.
Command Mode
Router configuration: Matrix>Router1(config-router)#
Command Defaults
None.
Example
This example shows how to set RIP timers to a 5 second update time, a 10 second invalid interval,
a 20 second holdown time, and a 60 second flush time:
basic Specifies a basic configuration for RIP routing timers.
update-seconds Specifies the rate (seconds between updates) at which
routing updates are sent. Valid values are 0 to 4294967295.
invalid-seconds Specifies the interval (in seconds) after which a route is
declared invalid. Valid values are 1 to 4294967295.
holdown-seconds Specifies the interval (in seconds) during which routing
information regarding better paths is suppressed. Valid
values are 0 to 4294967295.
flush-seconds Specifies the interval (in seconds) after which a route is
deleted. Valid values are 0 to 4294967295.
Matrix>Router1(config)#router rip
Matrix>Router1(config-router)#timers basic 5 10 20 60