Routing Protocol Configuration Command Set
Configuring RIP
Matrix DFE-Platinum and Diamond Series Configuration Guide 13-29
13.2.2.22 redistribute
Use this command to allow routing information discovered through non-RIP protocols to be
distributed in RIP update messages.
redistribute {connected | ospf process-id | static} [metric metric value]
[subnets]
Syntax Description
Command Syntax of the “no” Form
The “no” form of this command clears redistribution parameters:
no redistribute {connected | ospf process-id | static}
Command Mode
Router configuration: Matrix>Router1(config-router)#
Command Defaults
If metric value is not specified, 1 will be applied.
If subnets is not specified, only non-subnetted routes will be redistributed.
connected Specifies that non-RIP routing information discovered via
directly connected interfaces will be redistributed.
ospf Specifies that OSPF routing information will be
redistributed in RIP.
process-id Specifies the process ID, an internally used identification
number for each instance of the OSPF routing process run
on a router. Valid values are 1 to 65535.
static Specifies that non-RIP routing information discovered via
static routes will be redistributed. Static routes are those
created using the ip route command detailed in
Section 12.2.6.8.
metric metric
value
(Optional) Specifies a metric for the connected, OSPF or
static redistribution route. This value should be consistent
with the designation protocol.
subnets (Optional) Specifies that connected, OSPF or static routes
that are subnetted will be redistributed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix 2G4072-52 and is the answer not in the manual?

Enterasys Matrix 2G4072-52 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix 2G4072-52
CategorySwitch
LanguageEnglish

Related product manuals