SHOW CHASSIS
show chassis [slot <0-3>]
DESCRIPTION
This command is entered in the Super User Mode or Configuration Mode. This 
command provides a physical inventory of the chassis components for a specific 
slot or for the entire system. It does not indicate the liveness of the elements 
listed.
PARAMETERS
EXAMPLE
ALU(config)# show chassis
        Physical inventory at Thu Jul  8 14:49:33 2010
        System started approximately Thu Jul  8 14:29:53 2010
        Uptime is 0 days 0 hours 22 minutes 10 seconds
T1/E1 - Four port T1/E1 (active)
        Slot number: 1
        Part number: 902604-90
        Manufacturer:  ALU
        Description: Four port T1/E1
        Serial number:  DG0820000252
        Version: 03
        Revision: 00
        LoL firmware version: 2.2.71
        Loader version: 2.35
        ALU-OS version: 3.0.0
SE - Services engine (active)
        Slot number: 3
        Part number: 902601-90
        Manufacturer:  ALU
        Description: Services engine
        Serial number:  DG0818000126
        Version: 02
        Revision: 00
        CPU Version: 1 (Low Power Opteron)
        Opteron CPU Version: 1 
        Opteron CPU Frequency: 2193 MHz
        LoL firmware version: 2.2.71
        Loader version: 2.35
        ALU-OS version: 3.0.0
        MDC
                Serial number: DG0818000008
                Revision: 00
                Version: 03
BP - ALU OA740 chassis (passive)
Parameter Description