TIMERS LSA-GROUP-PACING
timers lsa-group-pacing <10-1800>
DESCRIPTION
This command is entered in the Router Configuration Mode. This command
changes the group pacing of LSAs.
PARAMETERS
DEFAULT VALUE
The default lsa-group pacing interval is 60 seconds.
EXAMPLE
ALU(config-router ospf 30)# timers lsa-group-pacing 100
Parameter Description
10-1800 The interval in seconds at which LSAs
are grouped and refreshed, check-
summed or aged.