INTERFACE MLFR
interface mlfr <1-256>
DESCRIPTION
This command is entered in the Configuration Mode. This command configures a
MLFR bundle interface that is identified by a user specified number.
PARAMETERS
DEFAULT VALUE
None.
EXAMPLE
ALU(config)# interface mlfr 100
ALU(config-if mlfr100)#
MLFR ACK INTERVAL
mlfr ack-interval <1-10>
DESCRIPTION
This command is entered in the Interface Configuration Mode. This command
configures the acknowledge interval.
PARAMETERS
DEFAULT VALUE
Default value is 4 seconds.
EXAMPLE
ALU(config-if Serial0/0:0)# mlfr ack-interval 5
Parameter Description
1-256 Bundle identification. This number can
vary from 1 - 256.
Parameter Description
1-10 Acknowledge interval in seconds. The
range of this interval is from 1 second to
10 seconds.