NO PPP LCP ECHO-INTERVAL
no ppp lcp echo-interval
This command is entered in the Interface Configuration Mode. The “no” command
sets the echo-interval to its default value. The default value is 10 seconds.
NO PPP LCP MAX-ECHO
no ppp lcp max-echo
This command is entered in the Interface Configuration Mode. The “no” command
sets the maximum number of unanswered LCP echo requests to is default, i.e., 5.
NO PPP TIMEOUT MAX-CONFIGURE
no ppp timeout max-configure
This command is entered in the Interface Configuration Mode. This command
sets the max-configure value to its default, i.e., 10.
NO PPP TIMEOUT MAX-FAILURE
no ppp timeout max-failure
This command is entered in the Interface Configuration Mode. The “no” command
sets the max-failure value to its default, 5.
NO PPP TIMEOUT MAX-TERMINATE
no ppp timeout max-terminate
This command is entered in the Interface Configuration Mode. The “no” command