Router Information Protocol
Left running head:
Chapter name (automatic)
488
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
Alcatel-Lucent
DEFAULT VALUE
• update: 30 seconds
• invalid: 180 seconds
• holddown: 180 seconds
• flush: 240 seconds
EXAMPLE
ALU(config-router rip)# timers basic 10 30 30 30
VALIDATE-UPDATE-SOURCE
validate-update-source
DESCRIPTION
Enter the command in the Router Configuration Mode. This command validates
the source IP address of incoming RIP routing updates.
PARAMETERS
None.
DEFAULT VALUE
Enabled.
EXAMPLE
ALU(config-router rip)# validate-update-source