registration timeout
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
821
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
REGISTRATION TIMEOUT
registration timeout <60-65535>
DESCRIPTION
This command is entered in the Client Object Configuration Mode. This command
is used to configure the interval (in seconds) at which the NHRP registration
requests are to be sent to the NHS.
PARAMETERS
DEFAULT VALUE
The default registration timeout is every two-third of the NHRP holdtime.
PLATFORMS SUPPORTED
OmniAccess 5740 USG
EXAMPLE
ALU(config-nhrp-alu-dmvpn)# registration timeout 600
RELEASE HISTORY
Release 3.0: command was introduced.
Parameter Description
60-65535 Specify interval (in seconds) at which the
NHRP registration requests are to be
sent to the NHS.